For the M32100T-SDI-E and M32170T-SDI (When
debugging)
(1) Mount NQPACK144SD on the foot pattern on the target
system.
(2) On top of (1), mount YQPACK144SD.
(3) Screw down the YQPACK144SD with YQ-GUIDE's.
(4) Set the clock select switch.
(5) Mount the M32182T2-PTC on the YQPACK144SD.
(6) Mount the M3T-PTC-CNV on the M32182T2-PTC.
(7) Connect the probe of the emulation pod and the
M32182T2-PTC via the SDI MCU control interface cable and
the SDI trace interface cable.
During board-mounted evaluation
(1) Mount the NQPACK144SD.
(2) Mount the M32182FxxFP on the NQPACK144SD.
(3) Mount the HQPACK144SD (option) on the NQPACK144SD.
Recommended Foot Pattern (Unit: mm)