To our customers,
Old Company Name in Catalogs and Other Documents
On April 1
st
, 2010, NEC Electronics Corporation merged with Renesas Technology
Corporation, and Renesas
Electronics Corporation took over all the business of both
companies.
Therefore, although the old company name remains in this document, it is a valid
Renesas Electronics document. We appreciate your understanding.
Renesas Electronics website: http://www.renesas.com
April 1
st
, 2010
Renesas Electronics Corporation
Issued by: Renesas Electronics Corporation (http://www.renesas.com)
Send any inquiries to http://www.renesas.com/inquiry
.
Zobrazit stránku 0
1 2 3 4 5 6 ... 31 32

Shrnutí obsahu

Strany 1 - To our customers

To our customers, Old Company Name in Catalogs and Other Documents On April 1st, 2010, NEC Electronics Corporation merged with Renesas Technology C

Strany 2

iPrefaceThank you for purchasing this user system interface cable (HS36049ECH61H) for the Renesas’soriginal microcomputer H8/36049 group.The HS36049EC

Strany 3 - User’s Manual

iiContentsSection 1 Configuration...1Section 2 Connection Proced

Strany 4 - Cautions

1Section 1 ConfigurationCAUTIONUse an IC149-080-017-B5 socket (manufactured byYAMAICHI ELECTRONICS Co., Ltd.) for the FP-80Apackage IC socket on th

Strany 5 - IMPORTANT INFORMATION

2Table 1 lists the HS36049ECH61H components. Please make sure you have all of thesecomponents when unpacking.Table 1 HS36049ECH61H ComponentsNo. Comp

Strany 6 - DISCLAIMER

3Section 2 Connection Procedures2.1 Connecting User System Interface Cable to Emulator Station (withChannel 3 of Serial Communication Interface for

Strany 7

4Emulator stationCable body connectorUser system interface cableE6000CTS screws (M3 x 6 mm)Figure 2 Connecting User System Interface Cable to Emulat

Strany 8 - SAFETY PAGE

52.2 Connecting User System Interface Cable to Expansion I/O Board(without Channel 3 of Serial Communication Interface for H8/36049Group)WARNINGAlways

Strany 9

6Cable body connectorUser system interface cableCTS screws (M3 x 6 mm)Expansion I/O board cableUSER INTERFACE CABLE6000 EMULATOE6000Figure 3 Connect

Strany 10

72.3 Connecting User System Interface Cable to User SystemWARNINGAlways switch OFF the user system and the emulatorproduct before the USER SYSTEM INTE

Strany 11 - Contents

82.3.3 Inserting Cable HeadCAUTIONCheck the location of pin 1 before inserting.Align pin 1 on the IC socket for an FP-80A package on the user system w

Strany 12 - Section 1 Configuration

Notice 1. All information included in this document is current as of the date this document is issued. Such information, however, is subject to chang

Strany 13

9Fasten the user system interface cable head to the IC socket for an FP-80A package on the usersystem with the four screws (M2 x 12 mm; with four flat

Strany 14

102.3.5 Fastening Cable BodyConnect the cable body to the cable head.Cable bodyCable headRemove jigUser systemPush two remove jigs.RemovingFigure 5

Strany 15 - CTS screws (M3 x 6 mm)

112.4 Recommended Dimensions for User System Mount PadFigure 6 shows the recommended dimensions for the mount pad (footprint) for the user systemwith

Strany 16

122.5 Dimensions for User System Interface Cable HeadThe dimensions for the user system interface cable head are shown in figure 7.Figure 7 Dimensio

Strany 17 - Expansion I/O board cable

132.6 Resulting Dimensions after Connecting User System Interface CableThe resulting dimensions, after connecting the user system interface cable head

Strany 18

14Section 3 Installing the MCU to the User SystemCAUTION1. Check the location of pin 1 before inserting.2. Use a Philips-type screwdriver whose head

Strany 19 - 2.3.3 Inserting Cable Head

15MCUPin 1IC socket (IC149-080-017-B5manufactured by YAMAICHI ELECTRONICS Co., Ltd.)User systemScrews (M2 x 8 mm)with flat washersSocket coverFigure 9

Strany 20

16Section 4 Verifying Operation1. When using the H8/36049 group E6000 emulator (HS3664EPI61H), turn on the emulatoraccording to the procedures descr

Strany 21 - 2.3.5 Fastening Cable Body

17Figure 10 shows the system clock oscillator on the user system interface cable and the subclockinput specifications.R2 270R1 1 MHCU04HCU04To E6000 e

Strany 22 - 0.65 ± 0.05

18Section 5 Notice1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cablehead before inserting the cable h

Strany 23

H8/36049 Group FP-80A User System Interface Cable for E6000 EmulatorUser’s ManualUser’s Manual Rev.1.0 2003.12HS36049ECH61H HS36049ECH61HERenesas

Strany 24

196. The P1 short connector is used for testing. Do not remove the inserted jumper pin.P113Figure 12 P1 Short Connector

Strany 25

H8/36049 Group FP-80A User System Interface Cable for E6000 Emulator User's ManualPublication Date: Rev.1.00, December 19, 2003Published by:

Strany 26

1753, Shimonumabe, Nakahara-ku, Kawasaki-shi, Kanagawa 211-8668 JapanH8/36049 Group FP-80AUser System Interface Cable for E6000 EmulatorREJ10B0097-01

Strany 27

CautionsKeep safety first in your circuit designs!1. Renesas Technology Corp. puts the maximum effort into making semiconductor productsbetter and mor

Strany 28 - To E6000

IIMPORTANT INFORMATIONREAD FIRST• READ this user's manual before using this user system interface cable.• KEEP the user's manual handy for f

Strany 29 - Section 5 Notice

IILIMITED WARRANTY Renesas warrants its user system interface cables to be manufacturedin accordance with published specifications and free from d

Strany 30 - Figure 12 P1 Short Connector

IIIState Law: Some states do not allow the exclusion or limitation of implied warranties or liability forincidental or consequential damages, so t

Strany 31

IVSAFETY PAGEREAD FIRST• READ this user's manual before using this user system interface cable.• KEEP the user's manual handy for future ref

Strany 32 - H8/36049 Group FP-80A

VWARNINGObserve the precautions listed below. Failure to do sowill result in a FIRE HAZARD and will damage the usersystem and the emulator product or