Revision Date: Jun. 10, 2005
Renesas Microcomputer Development Environment System
H8S Family / H8S/2600 Series
HS2635ECH61HE
Rev.1.00
H8S/2635 FP-128
User System Interface Cable
HS2635ECH61H User’s Manual
REJ10B0197
-
0100
Zobrazit stránku 0
1 2 3 4 5 6 ... 31 32

Shrnutí obsahu

Strany 1 - User System Interface Cable

Revision Date: Jun. 10, 2005 Renesas Microcomputer Development Environment System H8S Family / H8S/2600 Series HS2635ECH61HE Rev.1.00 H8S/

Strany 2

iPrefaceThank you for purchasing this user system interface cable (HS2635ECH61H) for the Renesas’original microcomputer H8S/2635 group.The HS2635ECH61

Strany 3

iiContentsSection 1 Configuration...1Section 2 Connection Proced

Strany 4

1Section 1 ConfigurationCAUTIONUse an NQPACK128RD socket (manufactured byTokyo Eletech Corporation) for the FP-128 packageIC socket on the user sys

Strany 5 - IMPORTANT INFORMATION

2Figure 1 HS2635ECH61H User System Interface Cable

Strany 6 - DISCLAIMER

3Table 1 lists the HS2635ECH61H components. Please make sure you have all of thesecomponents when unpacking.Table 1 HS2635ECH61H ComponentsNo. Compon

Strany 7

4Section 2 Connection Procedures2.1 Connecting User System Interface Cable to Emulator StationWARNINGObserve the precautions listed below. Failure

Strany 8 - SAFETY PAGE

5Figure 2 Connecting User System Interface Cable to Emulator Station

Strany 9

62.2 Connecting User System Interface Cable to User SystemWARNINGAlways switch OFF the user system and the emulatorproduct before the USER SYSTEM INTE

Strany 10

7User systemGuide pins4 projections to applyepoxy resin adhesive to Bottom view of IC soketPin 1Figure 3 Location Setting of IC Socket2.2.2 Solderin

Strany 11 - Contents

82.2.4 Fastening Cable HeadCAUTION1. Use the screwdriber provided for tightening screws.2. The tightening torque must be 0.054 N•m or less.If the appl

Strany 13

9Figure 4 Connecting User System Interface Cable to User System

Strany 14

102.2.5 Fastening Cable BodyConnect the cable body to the cable head.Cable bodyCable headRemove jigPush the remove jigRemovingUser systemFigure 5 Fa

Strany 15

112.3 Recommended Dimensions for User System Mount PadFigure 6 shows the recommended dimensions for the mount pad (footprint) for the user systemwith

Strany 16

122.4 Dimensions for User System Interface Cable HeadThe dimensions for the user system interface cable head are shown in figure 7.Figure 7 Dimensio

Strany 17 - 2.2.1 Installing IC Socket

132.5 Resulting Dimensions after Connecting User System Interface CableThe resulting dimensions, after connecting the user system interface cable head

Strany 18

14Section 3 Installing the MCU on the User SystemCAUTION1. Check the location of pin 1 before inserting.2. Use the screwdriver provided for tighteni

Strany 19

15Figure 9 Installing MCU to User System

Strany 20

16Section 4 Verifying Operation1. Start up the emulator according to the procedures described in the H8S/2646 E6000 EmulatorUser's Manual (HS26

Strany 21 - 2.2.5 Fastening Cable Body

17Section 5 Notice1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cablehead before inserting the cable h

Strany 22 - 23.00 ± 0.15

186. The P1 jumper socket is used for testing. Do not remove the inserted jumper pin.P1321Figure 12 P1 Jumper Socket

Strany 23

1. These materials are intended as a reference to assist our customers in the selection of the Renesas Technology Corp. product best suited to the cus

Strany 24

Renesas Microcomputer Development Environment System User's ManualH8S/2635 FP-128User System Interface Cable

Strany 25

Sales Strategic Planning Div. Nippon Bldg., 2-6-2, Ohte-machi, Chiyoda-ku, Tokyo 100-0004, Japanhttp://www.renesas.comRef

Strany 26

H8S/2635 FP-128User System Interface CableHS2635ECH61H User's Manual

Strany 28 - Section 5 Notice

IIMPORTANT INFORMATIONREAD FIRST• READ this user's manual before using this user system interface cable.• KEEP the user's manual handy for f

Strany 29

IILIMITED WARRANTY Renesas warrants its user system interface cables to be manufacturedin accordance with published specifications and free from d

Strany 30 - User's Manual

IIIState Law: Some states do not allow the exclusion or limitation of implied warranties or liability forincidental or consequential damages, so t

Strany 31 - RENESAS SALES OFFICES

IVSAFETY PAGEREAD FIRST• READ this user's manual before using this user system interface cable.• KEEP the user's manual handy for future ref

Strany 32

VWARNINGObserve the precautions listed below. Failure to do sowill result in a FIRE HAZARD and will damage the usersystem and the emulator product or