IMPORTANT INFORMATION
READ FIRST
• READ this user's manual before using this user system interface cable.
• KEEP the user's manual handy for future reference.
Do not attempt to use the user system interface cable until you fully understand its
mechanism.
User System Interface Cable:
Throughout this document, the term "user system interface cable" shall be defined as the
following product produced only by Renesas Technology Corp. excluding all subsidiary products.
User system interface cable (HS2238ECN61H)
The user system or a host computer is not included in this definition.
Purpose of the User System Interface Cable:
This user system interface cable is for connecting the emulator station and user system. This
user system interface cable must only be used for the above purpose.
Improvement Policy:
Renesas Technology Corp. (including its subsidiaries, hereafter collectively referred to as
Renesas) pursues a policy of continuing improvement in design, performance, functions, and
safety of the user system interface cable. Renesas reserves the right to change, wholly or partially,
the specifications, design, user's manual, and other documentation at any time without notice.
Target User of the User System Interface Cable:
This user system interface cable should only be used by those who have carefully read and
thoroughly understood the information and restrictions contained in the user's manual. Do not
attempt to use the user system interface cable until you fully understand its mechanism.
It is highly recommended that first-time users be instructed by users that are well versed in the
operation of the user system interface cable.
Zobrazit stránku 0
1 2 3 4 5 6 ... 23 24

Shrnutí obsahu

Strany 1 - IMPORTANT INFORMATION

I IMPORTANT INFORMATION READ FIRST • READ this user's manual before using this user system interface cable. • KEEP the user's manual handy

Strany 2 - DISCLAIMER

Section 1 Configuration 1 UTIONCA Use an NQPACK100SE socket (manufactured by Tokyo Eletech Corporation) for the TFP-100G package IC socket on

Strany 3

2 Table 1 lists the HS2238ECN61H components. Please make sure you have all of these components when unpacking. Table 1 HS2238ECN61H Components No.

Strany 4 - SAFETY PAGE

Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station WARNING Always switch OFF the user system and the

Strany 5

2.2 Connecting User System Interface Cable to User System WARNING Always switch OFF the user system and the emulator product before the USER S

Strany 6 - (HS2238ECN61H)

2.2.1 Installing IC Socket 1. Confirming the location of IC socket 5 UTIONCA After confirming the location of pin 1 on the IC socket, apply

Strany 7 - Cautions

2.2.2 Inserting Cable Head 6 UTIONCA Check the location of pin 1 before inserting. Align pin 1 on the IC socket for a TFP-100G package on the u

Strany 8 - Preface

Fasten the user system interface cable head to the IC socket for a TFP-100G package on the user system with the four screws (M2 x 10 mm) provided. Ea

Strany 9 - Contents

2.2.4 Connecting Cable Body to Cable Head Connect the cable body to the cable head. Cable bodyCable headRemove jigPush the remove jigRemovingUser sy

Strany 10 - Section 1 Configuration

2.3 Recommended Dimensions for User System Mount Pad Figure 6 shows the recommended dimensions for the mount pad (footprint) for the user system with

Strany 11

2.4 Dimensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 7. 45.748.64.04-φ2

Strany 12 - User system interface cable

II LIMITED WARRANTY Renesas warrants its user system interface cables to be manufactured in accordance with published specifications and free

Strany 13

2.5 Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after connecting the user system interface cable head

Strany 14 - system

Section 3 Installing the MCU to the User System 12 UTIONCA 1. Check the location of pin 1 before inserting. 2. Use the screwdriver provided fo

Strany 15 - 2.2.3 Fastening Cable Head

MCUPin 1IC socket (NQPACK100SEmanufactured by Tokyo Eletech Corporation)User systemScrews (M2 x 6 mm)Socket cover Figure 9 Installing MCU to User Sys

Strany 16

Section 4 Verifying Operation 1. When using the E6000 emulator for the H8S/2633 series, turn on the emulator according to the procedures described i

Strany 17

Section 5 Notice 1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable head before inserting the cable h

Strany 18 - Unit: mm

III State Law: Some states do not allow the exclusion or limitation of implied warranties or liability for incidental or consequential damages, so

Strany 19

SAFETY PAGE READ FIRST • READ this user's manual before using this user system interface cable. • KEEP the user's manual handy for future re

Strany 20 - 10.5 21.5

WARNING Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulato

Strany 21

H8S/2237, H8S/2238R Series TFP-100G User System Interface Cable (HS2238ECN61H) for E6000 Emulator User’s Manual ADE-xxx-xxx Rev. 1.0 4/1/03 Renesas

Strany 22

Cautions 1. Renesas neither warrants nor grants licenses of any rights of Renesas’s or any third party’s patent, copyright, trademark, or other intel

Strany 23

i Preface Thank you for purchasing this user system interface cable (HS2238ECN61H) for the Renesas’s original microcomputer H8S/2237, H8S/2238R serie

Strany 24 - Section 5 Notice

ii Contents Section 1 Configuration.....................1 Section 2 Connection Proc

Komentáře k této Příručce

Žádné komentáře