Renesas PLQP0176LB-A Technické informace

Procházejte online nebo si stáhněte Technické informace pro ne Renesas PLQP0176LB-A. Renesas PLQP0176LB-A Technical information [en] Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 56
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
To our customers,
Old Company Name in Catalogs and Other Documents
On April 1
st
, 2010, NEC Electronics Corporation merged with Renesas Technology
Corporation, and Renesas
Electronics Corporation took over all the business of both
companies.
Therefore, although the old company name remains in this document, it is a valid
Renesas Electronics document. We appreciate your understanding.
Renesas Electronics website: http://www.renesas.com
April 1
st
, 2010
Renesas Electronics Corporation
Issued by: Renesas Electronics Corporation (http://www.renesas.com)
Send any inquiries to http://www.renesas.com/inquiry
.
Zobrazit stránku 0
1 2 3 4 5 6 ... 55 56

Shrnutí obsahu

Strany 1 - To our customers

To our customers, Old Company Name in Catalogs and Other Documents On April 1st, 2010, NEC Electronics Corporation merged with Renesas Technology C

Strany 2

Rev. 1.00 Jul. 03, 2009 Page viii of xviii REJ10J2026-0100 State Law: Some states do not allow the exclusion or limitation of implied warran

Strany 3 - User’s Manual

Rev. 1.00 Jul. 03, 2009 Page ix of xviii REJ10J2026-0100 SAFETY PAGE READ FIRST • READ this user's manu

Strany 4

Rev. 1.00 Jul. 03, 2009 Page x of xviii REJ10J2026-0100 means WARNING or CAUTION. Example: CAUTION AGAINST AN ELECTRIC SHOCK means PROHIBITION.

Strany 5

Rev. 1.00 Jul. 03, 2009 Page xi of xviii REJ10J2026-0100 WARNING Warnings for AC Power Supply: • If the

Strany 6

Rev. 1.00 Jul. 03, 2009 Page xii of xviii REJ10J2026-0100 WARNING • If you smell a strange odor, hear an unusual sound, or see smoke coming fro

Strany 7 - IMPORTANT INFORMATION

Rev. 1.00 Jul. 03, 2009 Page xiii of xviii REJ10J2026-0100 CAUTION Cautions for AC Adapter: • Use only the

Strany 8

Rev. 1.00 Jul. 03, 2009 Page xiv of xviii REJ10J2026-0100 WARNING Observe the precautions listed below. Failure to do so will result in a

Strany 9 - DISCLAIMER

Rev. 1.00 Jul. 03, 2009 Page xv of xviii REJ10J2026-0100 Preface The R0E572167CFL10 is a user system interfa

Strany 10 - REJ10J2026-0100

Rev. 1.00 Jul. 03, 2009 Page xvi of xviii REJ10J2026-0100

Strany 11 - SAFETY PAGE

Rev. 1.00 Jul. 03, 2009 Page xvii of xviii REJ10J2026-0100 Contents Section 1 Configuration ...

Strany 12

Notice 1. All information included in this document is current as of the date this document is issued. Such information, however, is subject to chang

Strany 13

Rev. 1.00 Jul. 03, 2009 Page xviii of xviii REJ10J2026-0100

Strany 14

Section 1 Configuration Rev. 1.00 Jul. 03, 2009 Page 1 of 32 REJ10J2026-0100 Section 1 Configuration Fig

Strany 15

Section 1 Configuration Rev. 1.00 Jul. 03, 2009 Page 2 of 32 REJ10J2026-0100 125.090.090.05.81125.090.0110.020.049.060.035.053.0267.0241.035.012

Strany 16

Section 1 Configuration Rev. 1.00 Jul. 03, 2009 Page 3 of 32 REJ10J2026-0100 CAUTION Use the following ite

Strany 17 - Preface

Section 1 Configuration Rev. 1.00 Jul. 03, 2009 Page 4 of 32 REJ10J2026-0100 Table 1 R0E572167CFL10 Components No. Component Quantity Remarks

Strany 18

Section 2 Environmental Conditions Rev. 1.00 Jul. 03, 2009 Page 5 of 32 REJ10J2026-0100 Section 2 Enviro

Strany 19 - Contents

Section 2 Environmental Conditions Rev. 1.00 Jul. 03, 2009 Page 6 of 32 REJ10J2026-0100

Strany 20

Section 3 Connection Procedures Rev. 1.00 Jul. 03, 2009 Page 7 of 32 REJ10J2026-0100 Section 3 Connectio

Strany 21 - Section 1 Configuration

Section 3 Connection Procedures Rev. 1.00 Jul. 03, 2009 Page 8 of 32 REJ10J2026-0100 3.1.2 Assembling the IC

Strany 22

Section 3 Connection Procedures Rev. 1.00 Jul. 03, 2009 Page 9 of 32 REJ10J2026-0100 (NQPACK176SE manufact

Strany 23

SH7216 Group PLQP0176LB-AUser System Interface Converter BoardR0E572167CFL10 User’s ManualUser’s Manual Rev.1.00 2009.07Renesas Microcomputer Develo

Strany 24

Section 3 Connection Procedures Rev. 1.00 Jul. 03, 2009 Page 10 of 32 REJ10J2026-0100 3.2 Connection to the

Strany 25

Section 3 Connection Procedures Rev. 1.00 Jul. 03, 2009 Page 11 of 32 REJ10J2026-0100 Connect the flexible

Strany 26

Section 3 Connection Procedures Rev. 1.00 Jul. 03, 2009 Page 12 of 32 REJ10J2026-0100 ________When removing t

Strany 27

Section 3 Connection Procedures Rev. 1.00 Jul. 03, 2009 Page 13 of 32 REJ10J2026-0100 3.2.2 Connecting Us

Strany 28

Section 3 Connection Procedures Rev. 1.00 Jul. 03, 2009 Page 14 of 32 REJ10J2026-0100 EV-chip unitCommon use

Strany 29

Section 3 Connection Procedures Rev. 1.00 Jul. 03, 2009 Page 15 of 32 REJ10J2026-0100 3.2.3 Installing to

Strany 30

Section 3 Connection Procedures Rev. 1.00 Jul. 03, 2009 Page 16 of 32 REJ10J2026-0100 3.3 Connection to the

Strany 31

Section 3 Connection Procedures Rev. 1.00 Jul. 03, 2009 Page 17 of 32 REJ10J2026-0100 3.3.2 Connecting th

Strany 32

Section 3 Connection Procedures Rev. 1.00 Jul. 03, 2009 Page 18 of 32 REJ10J2026-0100 3.3.3 Adjusting the Sp

Strany 33 - (figure 5)

Section 3 Connection Procedures Rev. 1.00 Jul. 03, 2009 Page 19 of 32 REJ10J2026-0100 3.3.4 Connecting th

Strany 34 - Conector number

Rev. 1.00 Jul. 03, 2009 Page ii of xviii REJ10J2026-0100

Strany 35

Section 3 Connection Procedures Rev. 1.00 Jul. 03, 2009 Page 20 of 32 REJ10J2026-0100 User I/F Connector 1(C

Strany 36

Section 3 Connection Procedures Rev. 1.00 Jul. 03, 2009 Page 21 of 32 REJ10J2026-0100 3.4 Dimensions 3.4.

Strany 37

Section 3 Connection Procedures Rev. 1.00 Jul. 03, 2009 Page 22 of 32 REJ10J2026-0100 3.4.2 External Dimensi

Strany 38 - User system

Section 3 Connection Procedures Rev. 1.00 Jul. 03, 2009 Page 23 of 32 REJ10J2026-0100 3.4.3 Dimensions of

Strany 39 - (figure 10)

Section 3 Connection Procedures Rev. 1.00 Jul. 03, 2009 Page 24 of 32 REJ10J2026-0100 26.261.017.878.5User sy

Strany 40

Section 3 Connection Procedures Rev. 1.00 Jul. 03, 2009 Page 25 of 32 REJ10J2026-0100 26.248.017.865.5Spa

Strany 41 - 3.4 Dimensions

Section 3 Connection Procedures Rev. 1.00 Jul. 03, 2009 Page 26 of 32 REJ10J2026-0100 26.217.852.6IC socket(

Strany 42

Section 4 Installing the MCU to the User System Rev. 1.00 Jul. 03, 2009 Page 27 of 32 REJ10J2026-0100 Sect

Strany 43

Section 4 Installing the MCU to the User System Rev. 1.00 Jul. 03, 2009 Page 28 of 32 REJ10J2026-0100 IC sock

Strany 44 - Connected)

Section 5 Verifying Operation Rev. 1.00 Jul. 03, 2009 Page 29 of 32 REJ10J2026-0100 Section 5 Verifying

Strany 45

Rev. 1.00 Jul. 03, 2009 Page iii of xviii REJ10J2026-0100 1. This document is provided for reference purpo

Strany 46 - EV-chip unit

Section 5 Verifying Operation Rev. 1.00 Jul. 03, 2009 Page 30 of 32 REJ10J2026-0100 3. When connecting the E

Strany 47

Section 6 Notice Rev. 1.00 Jul. 03, 2009 Page 31 of 32 REJ10J2026-0100 Section 6 Notice 1. Before conne

Strany 48

Section 6 Notice Rev. 1.00 Jul. 03, 2009 Page 32 of 32 REJ10J2026-0100

Strany 49

SH7216 Group PLQP0176LB-AUser System Interface BoardUser's ManualPublication Date: Rev.1.00, July 3, 2009Publishe

Strany 50

Sales Strategic Planning Div. Nippon Bldg., 2-6-2, Ohte-machi, Chiyoda-ku, Tokyo 100-0004, Japanhttp://www.renesas.comRefer to

Strany 52

1753, Shimonumabe, Nakahara-ku, Kawasaki-shi, Kanagawa 211-8668 JapanSH7216 Group PLQP0176LB-AUser System Interface Converter BoardREJ10J2026-0100R0E

Strany 53 - User's Manual

Rev. 1.00 Jul. 03, 2009 Page iv of xviii REJ10J2026-0100

Strany 54 - RENESAS SALES OFFICES

Rev. 1.00 Jul. 03, 2009 Page v of xviii REJ10J2026-0100 IMPORTANT INFORMATION READ FIRST • READ this user&ap

Strany 55

Rev. 1.00 Jul. 03, 2009 Page vi of xviii REJ10J2026-0100 Target User of the Emulator Product: This emulator product should only be used by t

Strany 56 - R0E572167CFL10 User’s Manual

Rev. 1.00 Jul. 03, 2009 Page vii of xviii REJ10J2026-0100 LIMITED WARRANTY Renesas warrants its emul

Komentáře k této Příručce

Žádné komentáře