Renesas H8/3864 Series Technické informace

Procházejte online nebo si stáhněte Technické informace pro ne Renesas H8/3864 Series. Renesas H8/3864 Series Technical information Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 30
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
To our customers,
Old Company Name in Catalogs and Other Documents
On April 1
st
, 2010, NEC Electronics Corporation merged with Renesas Technology
Corporation, and Renesas Electronics Corporation took over all the business of both
companies. Therefore, although the old company name remains in this document, it is a valid
Renesas Electronics document. We appreciate your understanding.
Renesas Electronics website: http://www.renesas.com
April 1
st
, 2010
Renesas Electronics Corporation
Issued by: Renesas Electronics Corporation (http://www.renesas.com)
Send any inquiries to http://www.renesas.com/inquiry
.
Zobrazit stránku 0
1 2 3 4 5 6 ... 29 30

Shrnutí obsahu

Strany 1 - To our customers

To our customers, Old Company Name in Catalogs and Other Documents On April 1st, 2010, NEC Electronics Corporation merged with Renesas Technology C

Strany 2

V WARNING Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emul

Strany 3 - To all our customers

Cautions 1. Hitachi neither warrants nor grants licenses of any rights of Hitachi’s or any third party’s patent, copyright, trademark, or other inte

Strany 5

i Preface Thank you for purchasing this user system interface cable (HS3864ECF61H) for the Hitachi’s original microcomputer H8/3864 series and H8/388

Strany 6 - IMPORTANT INFORMATION

ii Contents Section 1 Configuration...1 Section 2 Connection P

Strany 7 - DISCLAIMER

1 Section 1 Configuration CAUTION Use an IC149-080-012-B5 socket (manufactured by YAMAICHI ELECTRONICS Co., Ltd.) for the FP-80B package

Strany 8

2 Table 1 lists the HS3864ECF61H components. Please make sure you have all of these components when unpacking. Table 1 HS3864ECF61H Components No.

Strany 9 - SAFETY PAGE

3 Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station WARNING Observe the precautions listed below.

Strany 10

4 Figure 2 Connecting User System Interface Cable to Emulator Station

Strany 11 - Cautions

5 2.2 Connecting User System Interface Cable to User System WARNING Always switch OFF the user system and the emulator product before the USE

Strany 12

Notice 1. All information included in this document is current as of the date this document is issued. Such information, however, is subject to chang

Strany 13 - Preface

6 2.2.3 Inserting Cable Head CAUTION Check the location of pin 1 before inserting. Align pin 1 on the IC socket for an FP-80B package on the us

Strany 14 - Contents

7 Fasten the user system interface cable head to the IC socket for an FP-80B package on the user system with the four screws (M2 x 12 mm; with four f

Strany 15 - CAUTION

8 2.2.5 Fastening Cable Body Connect the cable body to the cable head. Cable bodyCable headRemove jigPush the remove jigRemovingUser system Figure 4

Strany 16

9 2.3 Recommended Dimensions for User System Mount Pad Figure 5 shows the recommended dimensions for the mount pad (footprint) for the user system w

Strany 17

10 2.4 Dimensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 6. Figure 6

Strany 18

11 2.5 Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after connecting the user system interface cable

Strany 19

12 Section 3 Installing the MCU to the User System CAUTION 1. Check the location of pin 1 before inserting. 2. Use a Phillips-type screwdrive

Strany 20

13 MCUPin 1IC socket (IC149-080-012-B5manufactured by YAMAICHI ELECTRONICS Co., Ltd.)User systemScrews (M2 x 8 mm)with flat washersSocket cover Figur

Strany 21

14 Section 4 Verifying Operation 1. When using the H8/3864 series, H8/3887 series E6000 emulator (HS3880EPI60H), turn on the emulator according to

Strany 22 - 2.2.5 Fastening Cable Body

15 Figure 9 shows the system clock oscillator on the user system interface cable and the subclock input specifications. Figure 9 System Clock Osci

Strany 23 - 20.00 (min.)

Regarding the change of names mentioned in the document, such as Hitachi Electric and Hitachi XX, to Renesas Technology Corp.The semiconductor operati

Strany 24

16 Section 5 Notice 1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable head before inserting the ca

Strany 25

H8/3864 Series QFP-80BUser System Interface Cable(HS3864ECF61H) for E6000 EmulatorUser’s ManualUser’s ManualRev.0.1 2000.09

Strany 27

I IMPORTANT INFORMATION READ FIRST • READ this user's manual before using this user system interface cable. • KEEP the user's manual handy

Strany 28

II LIMITED WARRANTY Hitachi warrants its user system interface cables to be manufactured in accordance with published specifications and free

Strany 29

III State Law: Some states do not allow the exclusion or limitation of implied warranties or liability for incidental or consequential damages, so

Strany 30 - Section 5 Notice

IV SAFETY PAGE READ FIRST • READ this user's manual before using this user system interface cable. • KEEP the user's manual handy for futur

Komentáře k této Příručce

Žádné komentáře