Renesas H8S/2646 Series Technické informace

Procházejte online nebo si stáhněte Technické informace pro ne Renesas H8S/2646 Series. Renesas H8S/2646 Series Technical information [en] Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 31
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
To our customers,
Old Company Name in Catalogs and Other Documents
On April 1
st
, 2010, NEC Electronics Corporation merged with Renesas Technology
Corporation, and Renesas
Electronics Corporation took over all the business of both
companies.
Therefore, although the old company name remains in this document, it is a valid
Renesas Electronics document. We appreciate your understanding.
Renesas Electronics website: http://www.renesas.com
April 1
st
, 2010
Renesas Electronics Corporation
Issued by: Renesas Electronics Corporation (http://www.renesas.com)
Send any inquiries to http://www.renesas.com/inquiry
.
Zobrazit stránku 0
1 2 3 4 5 6 ... 30 31

Shrnutí obsahu

Strany 1 - To our customers

To our customers, Old Company Name in Catalogs and Other Documents On April 1st, 2010, NEC Electronics Corporation merged with Renesas Technology C

Strany 2

IILIMITED WARRANTY Hitachi warrants its user system interface cables to be manufacturedin accordance with published specifications and free from d

Strany 3 - To all our customers

IIIState Law: Some states do not allow the exclusion or limitation of implied warranties or liability forincidental or consequential damages, so t

Strany 4 - Cautions

IVSAFETY PAGEREAD FIRST• READ this user's manual before using this user system interface cable.• KEEP the user's manual handy for future ref

Strany 5 - User’s Manual

VWARNINGObserve the precautions listed below. Failure to do sowill result in a FIRE HAZARD and will damage the usersystem and the emulator product or

Strany 6

iPrefaceThank you for purchasing this user system interface cable (HS2282ECF61H) for the Hitachi’soriginal microcomputer H8S/2282 series.The HS2282ECF

Strany 7

iiContentsSection 1 Configuration...1Section 2 Connection Proced

Strany 8

1Section 1 ConfigurationCAUTIONUse an IC149-KS-11113-0 socket (manufactured byYAMAICHI ELECTRONICS Co., Ltd.) for the FP-100A packageIC socket on t

Strany 9 - IMPORTANT INFORMATION

2Table 1 HS2282ECF61H ComponentsNo. Component Quantity Remarks1 Cable body 1 Flat cable2 Cable head 13 IC socket 1 For the FP-100A package4 Socket cov

Strany 10 - DISCLAIMER

3Section 2 Connection Procedures2.1 Connecting User System Interface Cable to Emulator StationWARNINGObserve the precautions listed below. Failure

Strany 11

4Figure 2 Connecting User System Interface Cable to Emulator Station

Strany 12 - SAFETY PAGE

Notice 1. All information included in this document is current as of the date this document is issued. Such information, however, is subject to chang

Strany 13

52.2 Connecting User System Interface Cable to User SystemWARNINGAlways switch OFF the user system and the emulatorproduct before the USER SYSTEM INTE

Strany 14

62.2.4 Fastening Cable HeadCAUTION1. Use a Phillips-type screwdriver whose head matchesthe screw head.2. The tightening torque must be 0.098 N•m or le

Strany 15 - Contents

7Fasten the user system interface cable head to the IC socket for an FP-100A package on the usersystem with the two screws (M2.5 x 11 mm) provided. E

Strany 16 - Section 1 Configuration

82.2.5 Fastening Cable BodyConnect the cable body to the cable head.Cable bodyCable headRemove jigPush the remove jig.User systemRemovingFigure 4 Fa

Strany 17

92.3 Recommended Dimensions for User System Mount PadFigure 5 shows the recommended dimensions for the mount pad (footprint) for the user systemwith a

Strany 18

102.4 Dimensions for User System Interface Cable HeadThe dimensions for the user system interface cable head are shown in figure 6.Figure 6 Dimensio

Strany 19

112.5 Resulting Dimensions after Connecting User System Interface CableThe resulting dimensions, after connecting the user system interface cable head

Strany 20

12Section 3 Installing the MCU to the User SystemCAUTION1. Check the location of pin 1 before inserting.2. If the MCU does not operate correctly, cr

Strany 21 - 2.2.4 Fastening Cable Head

13Section 4 Verifying Operation1. When using the E6000 emulator for the H8S/2636 and H8S/2646 series, turn on the emulatoraccording to the procedure

Strany 22 - User system

14Section 5 Setting TRPB2, TRPA2, TRPA1, and TRPB1SwitchesIn this user system interface cable, TRPB2, TRPA2, TRPA1, and TRPB1 switches control thetr

Strany 23 - 2.2.5 Fastening Cable Body

Regarding the change of names mentioned in the document, such as Hitachi Electric and Hitachi XX, to Renesas Technology Corp.The semiconductor operati

Strany 24

15Section 6 Notice1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cablehead before inserting the cable h

Strany 25

166. The P1 short connector is used for testing. Do not remove the inserted jumper pin.Figure 12 P1 Short Connector

Strany 26

Cautions Keep safety first in your circuit designs! 1. Renesas Technology Corporation puts the maximum effort into making semiconductor products bett

Strany 27

H8S/2282 Series FP-100AUser System Interface Cable(HS2282ECF61H) for E6000 EmulatorUser’s ManualUser’s Manual Rev.2.0 2002.02

Strany 29 - Switches

Cautions1. Hitachi neither warrants nor grants licenses of any rights of Hitachi’s or any third party’spatent, copyright, trademark, or other intellec

Strany 31 - Figure 12 P1 Short Connector

IIMPORTANT INFORMATIONREAD FIRST• READ this user's manual before using this user system interface cable.• KEEP the user's manual handy for f