Rev.2.10 Apr 14, 2006 page 356 of 378
REJ09B0124-0210
M16C/6N Group (M16C/6NK, M16C/6NM) 23. Usage Notes
23.11 Thee-Phase Motor Control Timer Function
If there is a possibility that you may write data to TAi-1 register (i = 1, 2, 4) near Timer B2 overflow, read the
value of TB2 register, verify that there is sufficient time until Timer B2 overflows, before doing an immediate
write to TAi-1 register.
In order to shorten the period from reading TB2 register to writing data to TAi-1 register, ensure that no
interrupt will be processed during this period.
If there is not enough time till Timer B2 overflows, only write to TAi-1 register after Timer B2 overflowed.