Strany 1 - S550-SFWv3

Serial Flash Programmer Operation Manual S550-SFWv3 Sunny Giken Inc.

Strany 2 - Serial Flash Programmer

● Top Side View Connector Function SERIAL Cable connector for connecting the target. ● Bottom Side View Connector Function US

Strany 3 - Table of Contents

④ Complete Downloading ・ When the dialog “DownLoad Complete” appears, downloading is complete. ・ In “Multi Data Mode”, the data with the smallest

Strany 4

8.1.3. Programming ① Download ・ Download programming data to S550-SFWv3. *The programming data shall be downloaded to the main unit for stand-alo

Strany 5 - 1. Outline

8.2. Stand-alone Initialization You can initialize data that is stored in the S550-SFWv3 internal memory on unit basis for security purposes. The

Strany 6 - 1.2. System Configuration

8.3. Center Display Modes 8.3.1. Mode Transition Diagram Following illustrates mode transitions of S550-SFWv3 center display. (Single

Strany 7 - 2. Specifications

(Multi Data Mode) FUNCFUNCSTART STARTSTARTSTARTSTARTSTART "P.3"."P.4&quo

Strany 8 - 2.4. Programmable Device

8.3.2. Normal Display Mode This is the screen when power is turned on. The S550-SFWv3 displays the checksum lower 1 byte of the data stored in

Strany 9

8.3.4. Programming Information Display The S550-SFWv3 displays the programming information of the data stored in the internal memory of the main

Strany 10

8.3.6. Data Switch Display With the “Multi Data Mode”, you can select programming data on S550-SFWv3. Following shows how to select the data. *Whe

Strany 11

9. Messages and Warnings 9.1. Message Dialogs Display Contents S550-SFWv3 already started. Displayed when trying to start up the control soft

Strany 12

Display Contents Some Maintenance setting items has been edited. Do you want to replace the existing items? Confirmation whether to valida

Strany 13

2.6. Connector Pins Specifications ・ Connector Pins (S550-SFWv3 Main unit) ・ Model : XG4C-1434 OMRON Corporation ・ Pin Assignment (S550-

Strany 14 - 4. Connections

Display Contents Initialize... Displayed while initializing. Finish Displayed when programming has been complete. Initialize Stop... Displayed w

Strany 15

9.2. LED Status List Operation Condition LED Status No settings made by PC After “POWER” is lighted, “PASS”, “ID ERR”, and “FAIL” will blink o

Strany 16

Operation Condition LED Status Firmware updating “PASS”,“ID ERR” and “FAIL” will all be lighted. Firmware updating complete “PASS”, “ID ERR” and

Strany 17

9.4. List of Error Information on Center Display Center display status Descriptions "0","0" Programming is canceled after S

Strany 18

9.6. Initialized Settings (factory setting) List Items Default status (Factory setting) Programming data Data set in the device setting screen

Strany 19

10. Troubleshooting 10.1. Mode entry error occurs when programming The mode entry error occurs while preparing for programming. Following shows

Strany 20 - 5. Setting Up

10.6. Memory error occurs when programming Memory error occurs when the S550-SFWv3 main unit ROM is damaged. Following shows how to resolve. ① D

Strany 21

Version Revised contents Revised date Rev.A First edition 2010/03/29 Rev.B Changes of the whole ・The description has been changed from the “R

Strany 22

Rev.C 2.3. System Requirements ・Windows 7(32bit) has been added to OS. 5.1. Installing USB driver ・"5.1.1 Windows 7(32bit)" has been added

Strany 23

Rev.G 2.2.Function Specifications ・The Operation Mode has been changed. 2.7. Target Connecting Cable ・The explanation of Target Connecting Cable has

Strany 24

2.7. Target Connecting Cable 2.7.1. 14 – 14 Standard Cable The attached connecting cable is a straight cable. In case the connector specificat

Strany 25

Overseas Standard ・CE Mark Obtained (EMI:EN55011 Group1 ClassA ,EMS:EN61000-6-2) ・FCC Compliance This device complies with part 15 of the FCC Rul

Strany 26

2.7.4. 14 – 14 Custom2 Cable(model: S550-SFW-CB2) The optional connecting cable converts 14pin connector to 14pin(Applicable for RX Family(except

Strany 27

3. Circuitry Examples Refer to the file “S550-SFWv3 Examples of circuit for serial programming”in the enclosed CD-ROM. 4. Connections S550-SFW

Strany 28

4.2. Connection for Stand-alone Programming / Stand-alone Initializing The connection when you program from the lone S550-SFWv3 to the target (st

Strany 29

4.3. Connection for Remote Programming The connection when you program remotely to the target from the PC using the control software though S550-

Strany 30

 (When supplying voltage to the target board from S550-SFWv3 – Single CH Mode) Target connection cable Your tar

Strany 31

 (When supplying voltage to the target board using an external power supply - Multi CH Mode) S550-SFWv3 USB cable SFWv3 controlsoftware PC (OS:

Strany 32

 (When supplying voltage to the target board from S550-SFWv3 - Multi CH Mode) USB cable SFWv3 controlsoftware

Strany 33 - 6. Control Software

Serial Flash Programmer S550-SFWv3 The contents of this manual may be revised without notice. We, Sunny Giken Inc. shall not be responsible for

Strany 34

5. Setting Up 5.1. Installing USB driver When S550-SFWv3 is connected to a PC by USB, Windows automatically detects a new hardware and creates

Strany 35

iii) The following Dialog will be displayed. Press "Finish" button. Serial Flash Programmer[S550-SFWv3] Operat

Strany 36

5.1.2. Windows 7(64bit) i) Execute "dpinst.exe" of the “Driver64” folder. "Device Driver Installation Wizard" Dialog will be

Strany 37

iii) The USB driver package is being installed. Please wait for a moment. iv) The following Dialog will be displayed. Pre

Strany 38

5.1.3. Windows Vista i) “Found New Hardware” dialog will be displayed. Select “Locate and install driver software”. ii) Sele

Strany 39

iii) The driver files will be automatically copied and installation will be completed. Serial Flash Programmer[S550-SFWv3

Strany 40

5.1.4. Windows XP i) “Found New Hardware Wizard” dialog will be displayed. Select “Install from a list or specific location” and press [Next].

Strany 41

iii) The driver files will be automatically copied and installation will be completed. Serial Flash Programmer[S550-SFWv3] Operation Manual 26

Strany 42 - 6.2. Device Setting Screen

5.1.5. Windows 2000 i) ”Found New Hardware Wizard” dialog will be displayed. Press [Next]. ii) Select ”Search for a suita

Strany 43

iii) Select “Specify a location” and press [Next]. iv) Specify “USBDrv” folder in the attached CD-ROM for the area to copy fil

Strany 44

Table of Contents 1. Outline...

Strany 45

vi) The driver files will be automatically copied and installation will be completed. Serial Flash Programmer[S550-SFWv3] Operation

Strany 46

5.2. Installing Control Software Using the attached CD-ROM, execute “Setup.exe” in “Software” folder. The following is the software installatio

Strany 47

iii) Files are automatically copied and installation will be completed. 5.3. Uninstalling Control Software From the Con

Strany 48

6. Control Software 6.1. Main Screen 6.1.1. Main Screen (Single Data Mode, or Single CH Mode) (Multi Data Mode)

Strany 49

(Multi CH Mode) For “Multi CH Mode”, see “6.3.1 Maintenance Initial Setting Screen”. Serial Flash Programmer[S550-SFWv3] O

Strany 50

<Information section> Items Descriptions Shows MCU manufacture. Shows MCU series. Shows MCU model. * The device displayed (ECC) after the

Strany 51

<Project menu> Items Descriptions “New”: Discards the current settings and starts new setting. “Open...”: Opens a project file. “Save As

Strany 52

6.1.2. About Screen (Single CH Mode) (Multi CH Mode) Items Descriptions Shows the control software version. Sh

Strany 53

6.1.3. Initialize Setting Screen The following screen is displayed only in the "Multi CH Mode". <<S550-

Strany 54

6.1.4. UpLoad Setting Screen The following screen is displayed only in the "Multi CH Mode". <<S550-SFWv3

Strany 55

7.1.1.1. Process Flow up to Programming... 59 7.1.1.2.

Strany 56

6.1.5. DownLoad Setting Screen The following screen is displayed only in the "Multi CH Mode". <<S550-SF

Strany 57 - 6.4. Execution Screen

6.1.6. Program Setting Screen The following screen is displayed only in the "Multi CH Mode". <<S550-SFW

Strany 58

6.2. Device Setting Screen 6.2.1. Device Setting Screen <<Device section>> Items Descriptions Select MC

Strany 59

Items Descriptions Opens the clock frequency setting screen. (See “6.2.3 Clock Frequency Setting Screen”.) Shows main clock frequency. Shows per

Strany 60 - 7. Remote Mode

<<Main menu>> Items Descriptions “Main”: Moves to Main screen. *After a confirmation message, setting contents will be discarded.

Strany 61

6.2.2. Device Detail Display Screen Items Descriptions Shows MCU model. Shows the minimum value of the ROM block addr

Strany 62

6.2.4. User Program File Load Screen Select a user program file to load and press “Open”. When the file is loaded successfully,

Strany 63

6.2.5. User Program Edit Screen Items Descriptions Shows MCU model. Shows the user’s program name with the path

Strany 64

Items Descriptions Searches user’s program data or address. (See “6.2.6 User’s Program Data Search Screen”.) Fills the selected area with the id

Strany 65

6.2.8. User’s Program Data Saving Screen Items Descriptions Selects all area for saving. Selects address range for savi

Strany 66

1. Outline 1.1. Precautions Thank you for purchasing our product. Please read this operation manual carefully to understand the functions of t

Strany 67

6.2.10. ROM Area Block Information Setting Screen Items Descriptions Selects “Keep Device Lock Bits” for lock bit process

Strany 68

6.2.11. ROM Protection Setting Screen (R32C/100 Series) Items Descriptions Sets whether to execute BP Bit_Program for all BP0 and BP1

Strany 69

(78K,RL78 Family) Items Description Sets whether to execute Flash Option. Execution of the chip erase command is disabled. Execution of the

Strany 70

6.2.12. Input Vcc Setting Screen Items Descriptions Input vcc. Reflects the setting content and closes the screen. Discards the setting co

Strany 71

<Initial Setting section> Items Descriptions Enables saving the action log (operation execution log). Set saving destination for the ac

Strany 72

6.3.2. Password Setting Screen Items Descriptions Sets a password. Maximum of 8 single byte characters can be set. *The password is ref

Strany 73

6.3.3. Execution Operation Log Display Screen <Logging section> Items Descriptions Select a log file to displa

Strany 74

6.4. Execution Screen 6.4.1. Execution Screen (Single CH Mode) Serial Flash Programmer[S550-SFWv3] Operation Manual

Strany 75

(Multi CH Mode) <<Information section>> Items Descriptions Shows MCU manufacturer. Shows MCU series

Strany 76

<<Pass/Fail Counter section>> Items Descriptions Shows the number of successful programming. Shows the number of programming errors

Strany 77

1.2. System Configuration The entire system configuration of the Serial Flash Programmer S550-SFWv3 is illustrated below.

Strany 78

7. Remote Mode 7.1. Single CH Mode 7.1.1. Remote Programming 7.1.1.1. Process Flow up to Programming The following section describes the ope

Strany 79

7.1.1.2. Maintenance Settings With the control software, you can change S550-SFWv3 main unit setting. The following illustrates an example of th

Strany 80

② Save execution operation log ・ Check the “Ena” check box to save execution operation log. ・ To select the saving destination for execution op

Strany 81

③ Save device setting file ・ To select the saving destination for the device setting file, click the “Save Directory” button and select the des

Strany 82

④ Set password ・ Check the “Enable” check box to set a password to S550-SFWv3 main unit. Uploading data to program will require the password when

Strany 83

⑤ Select extended operation mode ・ Check the “Enable Expansion Action Mode” check box to select the extended operation mode. Standard operation m

Strany 84

⑥ Select power saving mode ・ Check the “Enable Power Save Mode” check box to set power saving mode of the S550-SFWv3 main unit. *When power sa

Strany 85

⑦ Select mute ・ Check the “Mute” check box to mute S550-SFWv3 main unit’s buzzer sound. Serial Flash Programmer[S550-SFWv

Strany 86 - Programming

⑧ Select “Multi Data Mode” ・ Check the “Enable Multi Data Mode” check box to set the “Multi Data Mode”. ・ Maximum of 4 data can be set or do

Strany 87

⑨ Select “Multi CH Mode” ・ Check the “Enable Multi CH Mode” check box to set the "Multi CH Mode". Please see "7.2.1.2 Maintenanc

Strany 88

2. Specifications 2.1. Specifications Operating Environment Ambient temperature : 0°C to 40°C Humidity: below 80% (non-condensing) Storage E

Strany 89

7.1.1.3. Data Settings With the control software, you can set the data to program. The following illustrates an example of the programming data

Strany 90

③ Select a device ・ Select the target device from “Maker” list, “MCU” list and “Type” list. ④ Select communication m

Strany 91

⑤ Select clock frequency ・ Click “Set Freq” button, input the clock frequency of the target board and select the clock multiplying rate from th

Strany 92

⑦ Edit data ・ Data is editable by clicking the “Edit” button, “Set ID” button, “Set Block” button” and/or “Set Protect” button. *For Editing, see

Strany 93

⑨ Confirm data ・ Confirm whether programming data is correct. ・ After checking, click the “Set” button and move to the main screen.

Strany 94

⑩ Save project (device setting) file (Single Data Mode) ・ You can save the contents set in the device setting screen and maintenance screen as a

Strany 95

⑪ Load a project file ・ Load the project file (device setting information and maintenance screen information) saved with the operation10 descri

Strany 96

⑫ Discard device setting (Single Data Mode) ・ You can discard the contents set in the device setting screen. ・ Select “New” from the “Project” m

Strany 97 - 8. Stand-alone Mode

⑬ Copy device setting (Only in the “Multi Data Mode”) ・ Select data of the copy origin and click the “Copy” button and move to the “Copy Informat

Strany 98

③ Start downloading ・ Click the “DownLoad” button. ・ The progress bar will show the downloading progress status. ・ Click “Cancel” to cancel

Strany 99

2.4. Programmable Device The Renesas built-in Flash Memory Microcomputers are the programmable devices. Some devices are under evaluation or no

Strany 100

④ Downloading complete ・ Downloading is complete when the execution screen appears. ⑤ Start programming ・ Click t

Strany 101 - Downloading”.)

⑥ Programming complete ・ When the “Result” area is yellow-green, programming is complete. When the area is in red, error occurred in programming.

Strany 102

7.1.2. Uploading You can upload the programming data stored in S550-SFWv3 to the control software (Upload). The following procedures show how to u

Strany 103 - 8.3. Center Display Modes

④ Start Uploading ・ The progress bar will show the uploading progress status. ・ Click “Cancel” to cancel uploading in midstream. *If

Strany 104

(Multi Data Mode) e.g.) Uploading 4th data stored in S550-SFWv3 to the 3rd data (i) Select uploading destination data number (1 through 4). Cl

Strany 105

7.1.3. Initialization You can initialize data that is stored in the S550-SFWv3 internal memory on unit basis for security purposes. The followings

Strany 106

7.2. Multi CH Mode 7.2.1. Remote Programming 7.2.1.1. Process Flow up to Programming The following section describes the operations from setti

Strany 107

7.2.1.2. Maintenance Settings With the control software, you can change S550-SFWv3 main unit setting. The following illustrates an example of th

Strany 108 - 9. Messages and Warnings

② Select Multi CH Mode ・ Check the “Enable Multi CH Mode” check box to set the "Multi CH Mode". ・ It is possible to Initialize/Upload

Strany 109

③ Start downloading ・ Click the “Program” button. ・ Select channels and click "OK" button. * In the "DownLoad" list, the it

Strany 110

2.5. S550-SFWv3 External Appearance The external appearance of S550-SFWv3 is shown below with descriptions of switches, LEDs, connectors and acc

Strany 111 - 9.2. LED Status List

*If the data in the S550-SFWv3 main unit and the data in the control software are identical, downloading will not be processed with the message “It

Strany 112 - 9.3. Buzzer Sound List

④ Downloading complete ・ Downloading is complete when the execution screen appears. ⑤ Start programming ・ Click t

Strany 113

⑥ Programming complete ・ When the “Result” area is yellow-green, programming is complete. When the area is in red, error occurred in programming.

Strany 114 - *With buzzer sound

7.2.2. Uploading You can upload the programming data stored in S550-SFWv3 to the control software (Upload). The following procedures show how to u

Strany 115 - 10. Troubleshooting

④ Start Uploading ・ The progress bar will show the uploading progress status. ・ Click “Cancel” to cancel uploading in midstream. *If

Strany 116

7.2.3. Initialization You can initialize data that is stored in the S550-SFWv3 internal memory on unit basis for security purposes. The followings

Strany 117

④ Start Initializing ・ Click the “Initialize” button and the confirmation dialog asking, “Do you want to initialize?” Click the “OK” button to sta

Strany 118

8. Stand-alone Mode 8.1. Stand-alone Programming 8.1.1. Process Flow up to Programming The following section describes the operations from se

Strany 119

8.1.2. Downloading You can store the data set with the control software in the S550-SFWv3 main unit (Download). The following procedure shows how

Strany 120 - ・FCC Compliance

③ Start Downloading ・ Click the “DownLoad” button. ・ The progress bar will show the downloading progress status. ・ Click “Cancel” to cancel