• Note when Time Stamp Setting is Changed
Even if the valid/invalid setting for the Time Stamp is switched in the [Trace Acquisition] dialog box, the
header character string in the [Trace] window is not changed.
When the valid/invalid setting is switched, open the [Trace] window again.
• Filter
When the trace filter function is used, the information of the Address and Source columns in the [Trace]
window does not match. When the filter function is used, ignore the source information displayed on the
Source column.
1.11 [Memory Mapping] Dialog Box
Even if the [Reset] button is clicked, the mapping information is not reset to the default setting. When the
mapping information is reset to the default setting, once close the [Memory Mapping] dialog box with the
[Close] button after clicking the [Reset] button.
1.12 Note on Setting Change Operation from BP Column
When the execution time measurement start point (+Time) or trace start point (+Trace) is clicked with the
right mouse button, a pop-up menu is displayed. An item in this pop-up menu may not be changed to
another one. In this case, change the item with double-clicking or from the [Breakpoints] window or
[Trace] window directly.
1.13 Note on [Registers] Window Operation during Program Execution
During program execution, when the [Registers] window is double-clicked, a dialog box to change the
register contents is displayed. However, the operation to change the register contents during program
execution becomes invalid.
1.14 [Breakpoints] Window
During user program execution, it is impossible to jump to the corresponding source line or address line
on the [Source] or [Disassemble] window from a breakpoint by using Go to Source in the pop-up menu
that is displayed on the [Breakpoints] window.
1.15 Profile Function
The E6000 HDI does not support the profile function (section 13.10, Profile-List, section 13.11,
Profile-Tree, and section 13.12, Profile-Chart, described in Hitachi Debugging Interface User's Manual).
1.16 [I/O Registers] Window
The E6000 HDI does not support the invalid module display and bit information display in the [I/O
Registers] window (described in section 8, Displaying Variables, in the Hitachi Debugging Interface
User's Manual).
1.17 Compare Memory
The Compare Memory function, which can be used by selecting [Compare...] from the [Memory] menu, is
not supported.
1.18 [Select Function] Dialog Box
The E6000 HDI does not support software breakpoint setting in the [Select Function] dialog box
(described in section 10, Selecting Functions, in the Hitachi Debugging Interface User's Manual).
1.19 Note on Radix in [Register] Dialog Box
The default input radix in the [Register] dialog box is hexadecimal regardless of the Radix setting. If you
want to input the radix other than hexadecimal, specify the prefix code such as B'.
1.20 Note on Moving Source File Position after Creating Load Module
When the source file is moved after the load module has been created, the [Open] dialog box, which
specifies the source file, may be displayed during debugging the created load module. Select the