H8SX/1668R Group E6000H PLQP0144KA-A
User System Interface Board
HS1668RECH61H User’s Manual
Renesas Microcomputer Development Environment System
H8SX Family / H8SX/1600 Series
HS1668RECH61HE
REJ10J1867-0200
Revision Date: Apr. 18, 2008
Rev.2.00
Zobrazit stránku 0
1 2 3 4 5 6 ... 43 44

Shrnutí obsahu

Strany 1 - Rev.2.00

H8SX/1668R Group E6000H PLQP0144KA-AUser System Interface BoardHS1668RECH61H User’s ManualRenesas Microcomputer Development Environment Syste

Strany 3

i Preface The HS1668RECH61H is a user system interface board that connects a user system for the H8SX/1668R PLQP0144KA-A (former package: FP-144L) pa

Strany 4

ii Content Preface ...i Section 1 Configurat

Strany 5 - IMPORTANT INFORMATION

1 Section 1 Configuration Figure 1 and table 1 show the external appearance and components, respectively, of the user system interface board for th

Strany 6 - DISCLAIMER

2 CAUTION Use an NQPACK144SD-ND socket (manufactured by Tokyo Eletech Corporation) as the PLQP0144KA-A-packaged IC socket on the user system

Strany 7

3 Section 2 Connection Procedures 2.1 Connecting the User System Interface Board to the User System WARNING Always switch OFF the user system

Strany 8 - SAFETY PAGE

4 To connect the board to the user system, follow the instructions below. 2.1.1 Installing the IC Socket After checking the location of pin 1 on the

Strany 9

5 2.1.2 Soldering the IC Socket After fastening, solder the IC socket for a PLQP0144KA-A package to the user system. CAUTION Be sure to complet

Strany 10

6 2.1.4 Fastening the IC Socket Connector CAUTION 1. Use the screwdriver provided for tightening screws. 2. The tightening torque must be 0.05

Strany 11 - Preface

7 User system interface boardUser systemPin 1Screws (M2 × 10 mm) (for fastening the board)IC socket (NQPACK144SD-NDmanufactured by Tokyo Eletech Corp

Strany 13 - Section 1 Configuration

8 2.2 Exchanging the Spacers of the Evaluation-Chip Board After connecting the user system interface board to the user system, be careful not to app

Strany 14 - CAUTION

9 2.3 Connecting the User System Interface Board to the Evaluation-Chip Board WARNING Observe the precautions listed below. Failure to do so

Strany 15

10 Connector No.UCN1 UCN1UCN2UCN2User system interface boardEvaluation-Chip Board Connector No.Board Connector No.Evaluation-chip board Figure 5 Co

Strany 16

11 2.4 Recommended Dimensions for the User System Mounting Pad (Footprint) Figure 6 shows the recommended dimensions for the mounting pad (footprint

Strany 17

12 2.5 Dimensions of the Evaluation-Chip Board and the User System Interface Board The dimensions of the evaluation-chip board and the user system i

Strany 18

13 2.6 Dimensions after Connecting the User System Interface Board The dimensions of the assembly after the user system interface board has been con

Strany 19

14 2.7 Using the Emulator without Connecting User System WARNING Always switch OFF the user system and the emulator product before the USER S

Strany 20 - (2.6MP × 25 mm)

15 SW1USERONUSEROFF Figure 9 SW1 Jumper Socket Spacer(2.6MQ x 13 mm) Figure 10 Attaching Spacers

Strany 21

16 Section 3 Installing the MCU to the User System CAUTION 1. Check the location of pin 1 before inserting. 2. Use the screwdriver provided f

Strany 22 - Connector No

17 MCUPin 1IC socket(NQPACK144SD-NDmanufactured byTokyo Eletech Corporation)User systemScrews (M2 x 6 mm)Socket cover Figure 11 Installing MCU to U

Strany 23 - (Footprint)

1. This document is provided for reference purposes only so that Renesas customers may select the appropriate Renesas products for their use

Strany 24 - Interface Board

18 Section 4 User System Interface Circuits The following user system interface circuits are required to use the emulator with the user system inte

Strany 25

19 MCUUser systemSub-MCUP30P31P34P35P36P37P20P2147 kΩVccP30P31P34P35P36P37P20P21TIOCA0TIOCB0TIOCA1TIOCB1TIOCA2TIOCB2TIOCA3TIOCB3 Figure 13 User Sys

Strany 26

20 47 kΩVccP16MCUUser systemSN74CB3Q3306AP16P14SN74CB3Q3306AP15P15P14Sub-MCUSCK5RxD5TxD547 kΩVcc Figure 14 User System Interface Circuit (3)

Strany 27 - (2.6MQ x 13 mm)

21 1 kΩ47 kΩVcc MD_CLKPM0-PM4 VBUS DrVcc USD- USD+ DrVssLPT16244Monitoring circuit MD_CLKPM0-PM4 VBUS DrVcc USD- USD DrV

Strany 28

22 47 kΩVccUHC14EPM7128VHC244_RESMCUEPM7128_RESUser system Figure 16 User System Interface Circuit (5) 47 kΩVccMCUEPM3256ATCADTRG0SW21P13PB6P133PB6

Strany 29

23 Section 5 Verifying Operation 1. Turn on the emulator according to the procedures described in the H8SX/1650 E6000H Emulator User's Manual

Strany 30 - SN74CBTLV3257

24 ⎯ To use the crystal resonator mounted on the evaluation-chip board Install the crystal resonator into the crystal resonator terminals on the eva

Strany 31

25 Section 6 Points for Caution 1. Before connecting any parts or cables, make sure that the pins at the pin 1 position on both sides are correctl

Strany 32

26 Section 7 Restrictions 1. Deep-software standby mode This emulator does not support deep-software standby mode. Note that the emulator switches

Strany 33

27 8. A/D converter In the emulator, the evaluation chip and the slave chip are used to implement functions of Unit 0 and Unit 1, respectively, of th

Strany 36 - Enlarged

H8SX/1668R Group E6000H PLQP0144KA-A User System Interface BoardHS1668RECH61H User's ManualPublication Date:

Strany 37 - Do not remove the jumpers

Sales Strategic Planning Div. Nippon Bldg., 2-6-2, Ohte-machi, Chiyoda-ku, Tokyo 100-0004, Japanhttp://www.renesas.comRefer to

Strany 39

H8SX/1668R Group E6000H PLQP0144KA-A User System Interface Board HS1668RECH61H User’s Manual

Strany 40

I IMPORTANT INFORMATION READ FIRST • READ this user's manual before using this user system interface board. • KEEP the user's manual handy

Strany 41

II LIMITED WARRANTY Renesas warrants its user system interface boards to be manufactured in accordance with published specifications and f

Strany 42 - RENESAS SALES OFFICES

III State Law: Some states do not allow the exclusion or limitation of implied warranties or liability for incidental or consequential damages,

Strany 43

IV SAFETY PAGE READ FIRST • READ this user's manual before using this user system interface board. • KEEP the user's manual handy for futur

Strany 44 - HS1668RECH61H User’s Manual

V WARNING Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emul

Komentáře k této Příručce

Žádné komentáře