(3) Select the line in the [Performance Analysis] window that has 1 in its [No] column and click the right-hand
mouse button to display a popup menu. Select [Set…] from this popup menu to display the [Performance
Analysis Properties] dialog box.
Figure 4.56 [Performance Analysis Properties] Dialog Box
(4) Select Time Of Specified Range Measurement from the [Measurement Method PA1] combo box.
(5) The parameter settings are as follows.
Enter sort in the [Range Name] edit box.
Click the […] button on the right of the [Start Address] edit box to display the [Input Function Range]
dialog box. Enter the function name sort in the [Function] edit box in this dialog box and then click
the [OK] button. The addresses for the function Sample::sort(long*) will now be set in the
[Start Address] and [End Address] edit boxes.
Figure 4.57 [Input Function Range] Dialog Box