5.7 Monitor Function
The foreground and background colors cannot be changed in some operating systems.
5.8 Performance Analysis Function
5.8.1 Errors
An error will be included in the measured performance as follows:
±one-resolution error (±20-ns error when the measurement resolution is 20 ns)
This error may occur when the user program execution starts or stops (breaks) or when the measurement start
or end condition is satisfied.
Frequency stability of the crystal oscillating module for performance analysis: ±0.01%
5.8.2 Notes
In all measurement modes, the interval between the end condition satisfaction and the next start condition
satisfaction must be longer than one-measurement-resolution time. If the interval is shorter than that, the
interval itself is included in the measured time.
In [Time Of Specified Range Measurement], measurement stops when an instruction is fetched outside the
specified range. In [Start Point To End Point Measurement] and [Start Range To End Range Measurement],
measurement stops when the specified end condition is satisfied. When the same addresses are specified for
these modes, the time measured in [Time Of Specified Range Measurement] is longer than that measured in
[Start Point To End Point Measurement] or [Start Range To End Range Measurement].
Execution time is measured by using address bus values in prefetch cycles. If the end address condition is
specified at an address near the instruction following a branch instruction or delayed slot instruction, correct
time cannot be measured. Check the bus trace display for the operation after the branch instruction prefetch
cycle, and specify the end address condition at the address in a prefetch cycle which will not be executed by
the branching.
Channel 1 is not available for performance analysis when the Point to Point trace mode is selected.
The resolution for the performance analysis function can be set in [Timer Resolution] of the [Configuration
Properties] dialog box. If the clock counter value is set as the resolution, the value shown in [RUN-TIME]
and [MAX-MIN-TIME] will be that of the clock counter (displayed in hexadecimal).
The counter for measurement has 24 bits, and the maximum measurement time is as given below depending
on the value set in [Timer Resolution].
Table 5.8 Maximum Measurement Time
Value of [Timer Resolution] Maximum Measurement Time
52 us Approximately 14 minutes
1.6 us Approximately 26 seconds
20 ns Approximately 0.33 second
The maximum measurement count for Access Count of Specified Range Measurement and Called Count of
Specified Range Measurement is 65,535.